• 1000A Precision Current Shunt
  • 1000A Precision Current Shunt

1000A Precision Current Shunt

1 μA to 1000 A
Lab Current Standard 1 μA to 1000 A
Current Range AC & DC Current Shunt AC & DC Current Meter
Input terminals can be placed in the rear panel (option)
Model : 1000A

  • Model 1000A has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1 Ω. The Shunt T/C is less than 10 ppm, and the internal current meter will measure from 1 μA to 1000 Amps. 
  • The five shunts selector and internal 5 1/2 Digit AC & DC Current Meter displays the respective shunt current. Connect an external DVM into output (with 5 1/2 digit higher) will increase both resolution and current reading accuracy.
  • Current range can be set and current value readback by optional interface.
1000a_specifications_en.jpg

  • 0.01 % High Accuracy
  • 5 1/2 Digit AC & DC Current Meter
  • Built-in Over Current Protection
  • Less than 10 ppm / ∘C ( Range 1000A:less than 50 ppm ℃)
  • High Stability & Reliability
  • Input terminals can be placed in the rear panel (option)
  • Optional Interface : GPIB、RS232、USB、LAN.

  • AC & DC Current Meter
  • AC & DC Current Sensor
  • AC & DC Power Supply
  • AC & DC Electronic Load
  • AC & DC Power Meter
 1000A Precision Current Shunt 1000A-R Precision Current Shunt Input terminals placed in the rear panel 
 GPIB Card RS-232 Card
 USB Card LAN Card Optional high current copper braid for load input