6050-4-X(3332F)USB PD 4 Channel + AB Switch Test System
APS-7000 Series Programmable Linear AC Power Sources Suitable test item & Specifications
For IEC-61000-4-11
3332F DC E-Load List of Specification and applicable features
4015A-2 List of Specification and applicable features
4013A List of Specification and applicable features
4032-PD List of Specification and applicable features
5303 AVR Suitable test item & Specifications
PFR-100L/100M Suitable test item & Specifications
99094-4 List of Specification and applicable features
- Can test 4 UUT at the same time to improve test efficiency and save test time and cost
- Select the required device configuration version ( Basic / Standard / Value / Complete version ) according to product testing requirements
- In addition to supporting USB PD, also supports QC2.0 / QC3.0 / PE+ / PE+2.0
- Highly cost-effective, fully functional modular design test system
- Operating environment of Windows 7 or higher (included)
- Open architecture software platform
6050-4-X(3332F)USB PD 4 Channel + AB Switch ATE Test System
USB PD Test items and equipment configuration table
6050 USB PD 4 channel + AB switch test system quick selection table
6050-4-A1-X basic version 4 channel + AB switch test system block diagram
6050-4-A1-X 4 Channel Test System Configuration
6050-4-A1-X The testable items of basic verion 4 channel + AB switch is as follows
6050-4-A1-X Basic version 4 channel + AB switch equipment configuration table
6050-4-B1-X Standard version 4 channel + AB switch test system is consisted of basic version adding 4032-PD Timing & Noise Meter x 2 can increase USB PD characteristics and timing and transient testingThe standard version system configuration is shown below.
6050-4-B1-X Block diagram of Standard version 4 channel + AB Switch test system
6050-4-B1-X 4 Channel Test System Configuration
6050-4-B1-X Standard version 4 channel + AB Switch adding 4032-PD x 2 can increase the test items as shown in the orange block below.
6050-4-B1-X Standard version 4 channel + AB Switch test system equipment configuration table
6050-4-C1-X Value version 4 channel + AB Switch test system Block diagram
6050-4-D1-X 4 Channel Test System Configuration
6050-4-C1-X Value version 4 channel + AB Switch test system change 4013A to 4015A can increase the test items as shown in the following green block
6050-4-C1-X Value version 4 channel + AB Switch test system equipment configuration table
The Complete version system configuration is shown below.
6050-4-D1-X Block diagram of Complete version 4 channel + AB Switch test system
6050-4-D1-X 4 Channel Test System Configuration
6050-4-D1-X Complete version 4 channel + AB Switch test system adds 5303 and PFR-100L D.C. Power Supply can increase test items as follow table
6050-4-D1-X Complete version 4 channel + AB switch test system equipment configuration table
6050-4-C1-X (3332F)USB PD 4 Channel + AB Switch ATE Test System(Value version) 6050-4-D1-X (3332F)USB PD 4 Channel + AB Switch ATE Test System(Complete version)